Repositorio Universidad del Cauca

Análisis comparativo de algoritmos de estimación de la longitud de zancada en marcha humana utilizando sistemas inerciales de medida

Mostrar el registro sencillo del ítem

dc.contributor.author Berruecos Gómez, Enmanuel
dc.contributor.author Chicue Restrepo, Marlio Alejandro
dc.date.accessioned 2022-12-02T16:10:42Z
dc.date.available 2022-12-02T16:10:42Z
dc.date.issued 2021
dc.identifier.uri http://repositorio.unicauca.edu.co:8080/xmlui/handle/123456789/5866
dc.description.abstract El objetivo del presente estudio es comparar la exactitud de diferentes algoritmos, para la estimación de la longitud de zancada en marcha humana, utilizando dispositivos IMU. En el ámbito médico, el estudio de la marcha ha interesado desde tiempos remotos, haciendo de este un estudio complejo y de gran utilidad del cual se pueden encontrar diversos sistemas de medición ampliamente utilizados. La variabilidad de la longitud de zancada durante el ciclo de marcha de un ser humano ha sido correlacionada con el riesgo de caída, la existencia de las enfermedades de Parkinson y de Huntington, y la presencia de lesiones cerebrales; lo que justifica la importancia del análisis de la marcha humana en las áreas de la salud y la ciencia en general, por lo cual, se desarrolló´ un experimento comparativo de la medición de la longitud de la zancada en una población de adultos sanos sin patologías con incidencia en la marcha, mediante dispositivos IMU, para determinar el grado de exactitud de ´estos algoritmos de estimación frente a un sistema basado en un algoritmo de visión artificial (sistema óptico de medida). Una vez completado el experimento, se realizó un análisis estadístico comparativo entre los algoritmos IMU y el algoritmo del sistema óptico de medida. Se determinó si estos grupos de datos pertenecían a una misma población mediante el estadístico Kruskal-Wallis; y mediante el error RMSE de todos los datos, se determinó el grado de exactitud de los algoritmos IMU frente al algoritmo basado en visión artificial. Como resultado, el estadístico Kruskal-Wallis rechazo la hipótesis nula H0, y se aceptó la hipótesis alternativa H1 de que por lo menos 1 grupo de datos de los algoritmos IMU proviene de una población con una distribución distinta al algoritmo basado en visión artificial. La exactitud de los algoritmos IMU tuvo un resultado poco satisfactorio en comparación de los resultados obtenidos mediante el sistema óptico de medida, con errores RMSE de hasta 83,12 % y promedio de zancada de hasta 15,72 centímetros. spa
dc.description.abstract The objective of the present study is the comparison of different algorithms exactness, for estimating human gait stride length, using IMU devices. In the medical field, the study of gait has been of interest since ancient times, making it a complex and highly useful study from which various widely used measurement systems can be found. The variability of stride length during the human gait cycle has been correlated with the risk of falling, the existence of Parkinson’s and Huntington’s diseases, and the presence of brain lesions; which justifies the importance of human gait analysis in the areas of health and science in general, whence, a comparative experiment was developed to measure the length of stride in a population of healthy adults without pathologies with incidence in gait, using IMU devices, to determine the exactness degree of these estimation algorithms against a system based on an artificial vision algorithm (optical measurement system). Once the experiment was completed, a comparative statistical analysis was performed between the IMU algorithms and the algorithm of the optical measurement system. It was determined whether these data groups belonged to the same population using the statistic Kruskal-Wallis; and by means of the RMSE error of all the data, the exactness degree of the IMU algorithms was determined compared to the artificial vision based algorithm. As a result, the statistician Kruskal-Wallis rejected the null hypothesis H0, and the alternative hypothesis H1 was accepted that at least 1 group of data from IMU algorithms comes from a population with a different distribution than the algorithm based on computer vision. IMU algorithms exactness had an unsatisfactory result compared with results obtained by using the optical measurement system, with RMSE errors of up to 83.12% and average stride of up to 15.72 centimeters. eng
dc.language.iso spa
dc.publisher Universidad del Cauca spa
dc.subject Longitud de zancada spa
dc.subject Dispositivos IMU spa
dc.subject Error RMSE spa
dc.subject Visión artificial spa
dc.subject Sistemas inerciales de medida spa
dc.subject Ciclo de marcha spa
dc.subject Stride length eng
dc.subject IMU devices eng
dc.subject RMSE error eng
dc.subject Machine visión eng
dc.subject Kruskal-Wallis eng
dc.subject Inertial measurement systems eng
dc.subject Gait cycle eng
dc.title Análisis comparativo de algoritmos de estimación de la longitud de zancada en marcha humana utilizando sistemas inerciales de medida spa
dc.type Trabajos de grado spa


Ficheros en el ítem

Este ítem aparece en la(s) siguiente(s) colección(ones)

Mostrar el registro sencillo del ítem

Buscar en DSpace


Listar

Mi cuenta