Repositorio Universidad del Cauca

Medical applications of low speed and resolution electrical impedance tomography

Mostrar el registro sencillo del ítem

dc.contributor.author Mosquera Leyton, Víctor Hugo
dc.date.accessioned 2023-10-23T14:52:51Z
dc.date.available 2023-10-23T14:52:51Z
dc.date.issued 2021
dc.identifier.uri http://repositorio.unicauca.edu.co:8080/xmlui/handle/123456789/8524
dc.description.abstract Urinary incontinence (UI), detrusor overactivity and prostatic hyperplasia are pathologies that cause urinary tract infections due to loss of sphincter control. UI is a common condition in elderly people, and between 15% to 35% of all adults suffer from severe UI. Additionally, people suffering from spinal cord injuries are highly prone to urinary tract infection due to the loss of micturition sensation. According to the World Health Organization, the prevalence of urinary tract diseases ranges from 40 to 80 people per million. Hence, UI is a public health problem. UI affects self-esteem and quality of life, and it is associated with higher rates of depression. UI also affects daily activities such as work, travel, social interaction, physical activity, sexual function, and sleep. Currently, catheterization is the most commonly used method for evacuating the bladder for people with UI, but the periodicity of the associated emptying procedures depends on an empirical estimate of the time it takes to fill the patient's bladder. Underestimating this period unnecessarily increases the number of catheterization procedures, thus increasing the risk of infections, cancers, and kidney stones. Conversely, overestimation of the catheterization period increases the risk of complications such as over-distension of the bladder wall, hydronephrosis, and autonomic dysreflexia. Ultrasound-based estimates are the gold standard to estimate bladder volume, with advantages of high portability and accuracy. However, ultrasound measurements must be performed by professionals, precluding continuous monitoring and limiting application to bladder volume monitoring. Due to the electrical conductivity of the urine, several bioimpedance techniques have been considered for bladder volume monitoring. Among these, Global Impedance (GI), which presents a high accuracy in volume estimation for the following configurations: (1) simple ring electrode arrangement with adjacent patterns for injection and measurement, (2) two vertical lines V2L electrodes arrangement with opposite patterns for injection and measurement. Other proposed approaches for bladder monitoring are: Voltage Change Ratios (VCR), Impedance Ratio Method (IRM) and Focused Impedance Method (FIM). Which present high sensitive to changes in the conductivity, just like GI. Therefore, these approaches are not suitable for long-term monitoring of the bladder, because the conductivity of urine varies with health status and diet. The robustness of a new proposal based on FIM was evaluated in a bladder phantom, presenting a low sensibility to the conductivity uncertainty of the phantom; being a promising technique for long-term monitoring of the bladder and would support the assisted bladder emptying process. eng
dc.language.iso eng
dc.publisher Universidad del Cauca spa
dc.rights.uri https://creativecommons.org/licenses/by-nc-nd/4.0/
dc.subject Medical application eng
dc.subject EIT eng
dc.subject Low temporal eng
dc.subject Temporal variability eng
dc.title Medical applications of low speed and resolution electrical impedance tomography eng
dc.type Tesis doctorado spa
dc.rights.creativecommons https://creativecommons.org/licenses/by-nc-nd/4.0/
dc.type.driver info:eu-repo/semantics/doctoralThesis
dc.type.coar http://purl.org/coar/resource_type/c_db06
dc.publisher.faculty Facultad de Ingeniería Electrónica y Telecomunicaciones spa
dc.publisher.program Doctorado en Ciencias de la Electrónica spa
dc.rights.accessrights info:eu-repo/semantics/openAccess
dc.type.version info:eu-repo/semantics/acceptedVersion
dc.identifier.instname
dc.identifier.reponame
oaire.accessrights http://purl.org/coar/access_right/c_abf2
dc.identifier.repourl
oaire.version http://purl.org/coar/version/c_ab4af688f83e57aa


Ficheros en el ítem

Este ítem aparece en la(s) siguiente(s) colección(ones)

Mostrar el registro sencillo del ítem

https://creativecommons.org/licenses/by-nc-nd/4.0/ Excepto si se señala otra cosa, la licencia del ítem se describe como https://creativecommons.org/licenses/by-nc-nd/4.0/

Buscar en DSpace


Listar

Mi cuenta